COVID-19 and respiratory support devices


Por: Pons-Odena, M, Valls, A, Grifols, J, Farre, R, Lasosa, FJC and Rubin, BK

Publicada: 1 sep 2020 Ahead of Print: 20 jun 2020
Resumen:
There are significant logistical challenges to providing respiratory support devices, beyond simple oxygen flow, when centres run out of supplies or do not have these devices at all, such as in low resource settings. At the peak of the COVID-19 crisis, it was extremely difficult to import medical equipment and supplies, because most countries prohibited the medical industry from selling outside of their own countries. As a consequence, engineering teams worldwide volunteered to develop emergency devices, and medical experts in mechanical ventilation helped to guide the design and evaluation of prototypes. Although regulations vary among countries, given the emergency situation, some Regulatory Agencies facilitated expedited procedures. However, laboratory and animal model testing are crucial to minimize the potential risk for patients when treated with a device that may worsen clinical outcome if poorly designed or misused. (C) 2020 Elsevier Ltd. All rights reserved.

Filiaciones:
Pons-Odena, M:
 Univ Barcelona, Pediat Intens Care & Intermediate Care Dept, St Joan de Deu Univ Hosp, Esplugas de Llobregat, Spain

 Santa Rosa, Immune & Resp Dysfunct Res Grp, Santa Rosa 39-57, Esplugas de Llobregat 08950, Spain

Valls, A:
 Univ Barcelona, Innovat Dept, St Joan de Deu Univ Hosp, Esplugas de Llobregat, Spain

:
 Fundacio Inst Invest Ciencies Salut Germans Trias, Comparat Med & Bioimage Ctr Catalonia CMCIB, Carretera Can Ruti,Cami Tanatori S-N, Barcelona 08916, Spain

Farre, R:
 Univ Barcelona, Fac Med & Ciencies Salut, Unitat Biofis & Bioengn, Barcelona, Spain

 CIBER Enfermedades Resp, Madrid, Spain

 Inst Invest Biomed August Pi Sunyer, Barcelona, Spain

Lasosa, FJC:
 Univ Barcelona, Pediat Intens Care & Intermediate Care Dept, St Joan de Deu Univ Hosp, Esplugas de Llobregat, Spain

 Santa Rosa, Immune & Resp Dysfunct Res Grp, Santa Rosa 39-57, Esplugas de Llobregat 08950, Spain

Rubin, BK:
 Virginia Commonwealth Univ, Childrens Hosp Richmond VCU, Sch Med, 1000 East Broad St, Richmond, VA 23298 USA
ISSN: 15260542





Paediatric Respiratory Reviews
Editorial
W. B. Saunders Co., Ltd., THE BOULEVARD, LANGFORD LANE, KIDLINGTON, OXFORD OX5 1GB, OXON, ENGLAND, Reino Unido
Tipo de documento: Review
Volumen: 35 Número:
Páginas: 61-63
WOS Id: 000566769100013
ID de PubMed: 32690356
imagen Green Published, Bronze

MÉTRICAS